Pioneer® Dual Zone Outdoor Section 230V 21.5 SEER Aire acondicionado multisplit y bomba de calor

Pioneer® Dual Zone Outdoor Section 230V 21.5 SEER Aire acondicionado multisplit y bomba de calor

SKU: YN020GMFI22M2E

Precio habitual $1,358.00
Precio de venta $1,358.00 Precio habitual $1,630.00

Agotado

  • Estimated delivery if ordered today: Jul 20 - Jul 24
Payment & Security
Métodos de pago
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Why buy from our store?

  • Free Shipping for Orders Above $299
  • Dedicated Product Support Included
  • Wholesale Price Directly From Factory

Descripción general

Resumen

  • SECCIÓN EXTERIOR SÓLO para Zona Dual (2)
  • Versión de inversor de CC de ultra alta eficiencia ++
  • Capacidad de enfriamiento: 18,000 BTU/H Nominal (Rango: 4,950 MIN ~ 23,000 MAX ) con eficiencia de 21.5 SEER
  • Capacidad de calefacción: 19 000 BTU/H nominales (rango: 4900 MIN ~ 23 000 MAX ) con eficiencia de 10,6 HSPF
  • Voltaje: 208~230 V, 60 Hertz, monofásico
  • Con carga de fábrica para un conjunto de líneas de hasta 25' por circuito
  • Estrella de energía Certificado
  • Funcionamiento silencioso como un susurro
[[REFRIGERANTE]]

Información Técnica

Certificaciones

Certificaciones Pioneer Mini Split

Datos de rendimiento

  • Fuente de alimentación: 208~230V, 60Hz, 1Ph
  • Protocolo de comunicación: bucle actual
  • Carga mínima-máxima adjunta: 12,000~24,000 BTU/h
  • Capacidad nominal de refrigeración: 18 000 BTU/h
  • Rango de capacidad de refrigeración: 4950~23 000 BTU/h
  • Enfriamiento SEER (sin ductos): 21.5 BTU/w
  • Capacidad nominal de calefacción: 19 000 BTU/h
  • Rango de capacidad de calentamiento: 4,950~23,000 BTU/h
  • Calefacción HSPF (sin conductos): 10,6 BTU/w
  • Tipo de refrigerante: R410a
  • Área adecuada: 600~800 pies cuadrados
  • Nivel de sonido: 59,5 dB(A)
  • Dimensiones netas (WDH): 35 x 13,5 x 26,5 pulgadas
  • Dimensiones de la caja (WDH): 40.5 x 17.25 x 29.5 pulgadas
  • Peso neto/bruto: 100/109 libras

Modelos interiores a juego

Combinaciones de Zona Dual

Clasificación dos unidades
Muro: 9 + 9 9 + 9
Canalizado: 9 + 9 9 + 12
12 + 12

Unidades compatibles de 9,000 BTU

Unidades compatibles de 12,000 BTU

    mín. / Máx. Cargando

    12.000 / 24.000 BTU/h.

    notas

    Cada unidad interior conectada funcionará a una capacidad autorregulada aleatoria, según la demanda real que mida de la zona a la que sirve (entre el 30 % y el 100 % de su capacidad nominal o APAGADA). La unidad exterior también autorregulará su capacidad de salida, en función de la demanda total que lea de todas las unidades interiores que funcionan simultáneamente en un momento dado.

    Con sistemas multisplit, la demanda total de la unidad exterior rara vez superará el 67 % de la capacidad total disponible del grupo de unidades interiores combinadas debido a las fluctuaciones de carga. Aunque muy raramente, siempre y cuando la demanda total del grupo interior combinado supere la capacidad nominal de la unidad exterior, la capacidad de cada unidad interior se anotará en consecuencia.

    Para aplicaciones de calefacción de alta demanda, es posible que sea necesario reducir los límites máximos de carga en un 10-15 % para evitar riesgos de bajo rendimiento en algunas condiciones extremas.

    Manuales y Descargas

    Pioneer® Product Series

    Estrella de energía

    Questions & Answers

    Have a Question?

    Ask a Question
    • I know 25 ft per lineset is the precharged max, but what if I use a 16 foot lineswt for 1 head and a 33 foot line set for the other, will the second set still need to be charged even though it is under the 50 foot of charge in the unit?

      As long as it adds up to 50' or less you're covered. So with 49' total you would be good there.

    • What ambient temperature is this good for? -15* F?

      This system heats down to -13°F outside temperatures.

    • Can I connect a 12000 and a 9000 to this unit

      Yes you definitely can.

    • If I buy a dual zone YN020GMFI22M2D, can buy install one indoor unit now and then buy the second indoor and install at a later date?

      Yes you can, that would not be a problem at all.

    • What AMP Breaker does this require?

      This would take a 20A double-pole breaker. The corresponding wire would be 12 AWG, with 2 hots and a ground, no neutral.

    • Can I run a single 18kbtu indoor unit with this outdoor unit.

      You cannot, you would need the triple-zone system, which is the smallest multi-zone that can take an 18K BTU head. Click here for more info.

    • Do both indoor units have to be heating/cooing to the same temperature or can they be set independently?

      The two attached heads can have their set temperatures be indepedently configured, but they must be in the same mode (of either COOL or HEAT).

    • free shipping?

      Yes all prices include shipping.

    • What size hole do I need to drill through the brick for the refrigeration lines for an 18K dual system?

      It would be a 2.5" diameter hole per each set of lines.

    • REFRIGERANT R410A Pre-Charged Outdoor Unit, accommodating refrigerant line lengths up to 25 ft. per circuit. The indoor units have a 33 ft and 50 ft line options. Can they be used with this outdoor unit?

      Yes they certainly can, but you will likely need to top off the condenser with some additional R410a to accomodate those longer lines.

    • Is it possible to run 2(2) 9,000 btu inside units with (1) 12,000 btu Duel split outside unit?

      Yes, this is a valid combination. See all combinations here.

    • Can I run a 9k and an 18K off this unit. In Okeechobee Fl

      The dual zone system cannot take an 18,000 BTU indoor unit. The triple-zone is the smallest multi-zone condenser that can. For more info see our matching table here.

    • Can i run (2) 12,000 BTU units on this outdoor model

      Yes, that would be a compatible configuration.

    • Can a 9000 and 12000 wall units be connected to this dual zone and if not what outdoor unit would be needed

      Yes they can, this would be valid.

    • What outside temperature does this unit cease to heat at?

      It would continue to heat down to -13°F outside temperature.

    • Can I wire two 9000 wt mini splits with this unit

      You cannot. These are the wall mounted 9,000 BTU units that are compatible with this condenser.

    • what size breaker & wire do I need

      It would take a 20A double pole breaker with 12 AWG wire.

    • I have a dual head unit can I run one head on air conditioning and the second head unit on heat at the same time?

      You cannot, it will throw a conflict error.

    • LINE LENGTHS UP TO 80 ft, Is it possible?

      You can have 80 ft for one indoor unit, but the maximum total that should be connected to this condenser should not exceed 100 ft combined.

    • Can I use only one indoor unit while the other unit remains off for a certain period of time?

      Yes you can, this would not be a problem.

    • Can I hook a two 12,000 btu heads up to this unit?

      Yes you can, this is a valid combination.

    • can i hook a 18000 btu and a 9000 btu to this unit

      You cannot. For an 18K head, you would need to use the triple-zone unit.

    • What is the minimum outdoor temperature this unit will operate at?

      Heating: -13°F / Cooling: 5°F

    • Would it be possible to install just one indoor unit then in a few weeks add a second indoor unit (understanding that the proper line set evacuation must be performed each time) ?

      This would not be a problem at all.

    • what amp breaker does the dual-zone 230 volt 21.3 seer require?

      This particular unit takes a 20A double-pole breaker with 12 AWG wire.

    • How can you connect a 12K indoor unit to the dual or three zone outdoor? Isn't the 12K indoor 1/4 x 1/2 & the outdoor 2 or 3 zone 1/4 x 3/8 only?

      All multi-zone condensers come included with the required adapters for this purpose.

    • can I hook a 9000 btu and a 12000 btu to this unit ?

      Yes, this dual can support 9K+9K, 12K+9K, or 12K+12K configurations.

    • If paired with 2x12k indoor unit, does it give me 24k continuous cooling or is it going to be only at 18k rated continuously?

      You can connect a bit more in capacity than what the outdoor unit itself is rated for. This is useful for when you're using one unit at a time. In the event that both of the indoor units are on and running at full demand at the same time (rarely/never happens), then the total combined BTU output will be attenuated down to the rating of the outdoor unit, in this case 17000-19000 BTU.