Saltar al contenido

Welcome to PIONEER OFFICIAL STORE | Call us at: (800) 919-0150

Multi-Zone Quantum Ultra™ Mini Split Outdoor Units

Energy-Star

Pioneer® Multi (5) Circuit Quantum Ultra Series 22 SEER2 Quint Zone Outdoor Section Inverter++ Energy-Star Air Conditioner Heat Pump 230V

Pioneer® Multi (5) Circuit Quantum Ultra Series 22 SEER2 Quint Zone Outdoor Section Inverter++ Energy-Star Air Conditioner Heat Pump 230V

Tipo: YNL-24

SKU: YN050GLSI24M5G

Precio habitual $3,138.00
Precio de venta $3,138.00 Precio habitual $4,479.00
Envío calculado al finalizar la compra.

Disponible en stock

  • Estimated delivery if ordered today: Dec 10 - Dec 14
Outdoor Unit Only

This listing is for an outdoor condensing unit only. It it intended to be paired with compatible indoor units to form a complete system. Use our matching table to configure a compatible system.

Payment & Security
Métodos de pago
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Why buy from our store?

  • Free Shipping for Orders Above $299
  • Dedicated Product Support Included
  • Wholesale Price Directly From Factory

Summary

  • Ultra High Efficiency Quint Zone (5 Circuit) Outdoor Condensing System
  • Cooling Capacity: 42,000 BTU with 22.0 SEER2 / 11.2 EER2 efficiency
  • Heating Capacity: 42,000 BTU with 10.0 HSP2 / 3.5 C.O.P. efficiency
  • Energy-Star Cold-Climate Designated Performance
  • Wide Ambient Operation Range (As low as -13°F in Heating / As high as 131°F in Cooling)
  • Factory Precharged to Cover Up to 125 Ft. of Total Combined Attached Lineset Length
  • Can be Utilized as a Stronger Quad or Triple or Dual-Zone System by Leaving 3rd and/or 4th and/or 5th Zones Closed

Performance

  • Power Supply: 208~230V, 60Hz, 1Ph
  • Communication Protocol: Current Loop
  • Min-Max Load Attached: 18,000~63,000 BTU/h
  • Cooling Rated Capacity (Ductless): 42,000 BTU/h
  • Cooling Rated Capacity (Ducted): 41,000 BTU/h
  • Cooling SEER2 (Ductless): 22.0 BTU/W.h
  • Cooling SEER2 (Ducted): 20.0 BTU/W.h
  • Cooling EER2 (Ductless): 11.2 BTU/W.h
  • Cooling EER2 (Ducted): 11.7 BTU/W.h
  • Heating Rated Capacity (Ductless): 42,000 BTU/h
  • Heating Rated Capacity (Ducted): 42,000 BTU/h
  • Heating HSPF2 (Ductless): 10.0 BTU/W.h
  • Heating HSPF2 (Ducted): 8.5 BTU/W.h
  • Heating C.O.P.2 5°F (Ductless): 2.0 W/W
  • Heating C.O.P.2 5°F (Ducted): 2.0 W/W
  • Refrigerant Type: R454B
  • Suitable Area: 1000~1600 sq ft
  • Sound Level: 65.0 dB(A)
  • Circuit Breaker Utilized: 40A (double-pole)
  • Net Dimensions (WDH): 42-1/4 x 18-3/8 x 33-1/2 Inches
  • Carton Dimensions (WDH): 44-5/8 x 20-7/8 x 38-1/8 Inches
  • Net / Gross Weight: 145 / 170 lbs
  • AHRI Reference: 217048771 (Ductless) / 217048775 (Ducted)

Manuals & Documents

Submittal Sheets

Quint Zone Combinations (in thousands BTU)

Two Units Three Units Four Units Five Units
9 + 9 9 + 9 + 9 9 + 9 + 9 + 9 9 + 9 + 9 + 9 + 9
12 + 9 12 + 9 + 9 12 + 9 + 9 + 9 12 + 9 + 9 + 9 + 9
12 + 12 12 + 12 + 9
12 + 12 + 9 + 9 18 + 9 + 9 + 9 + 9
18 + 9 12 + 12 + 12
12 + 12 + 12 + 9 24 + 9 + 9 + 9 + 9
18 + 12
18 + 9 + 9 12 + 12 + 12 + 12 12 + 12 + 9 + 9 + 9
18 + 18 18 + 12 + 9
18 + 9 + 9 + 9
18 + 12 + 9 + 9 + 9
24 + 9 18 + 12 + 12 18 + 12 + 9 + 9 24 + 12 + 9 + 9 + 9
24 + 12 18 + 18 + 9 18 + 12 + 12 + 9 18 + 18 + 9 + 9 + 9
24 + 18 18 + 18 + 12 18 + 12 + 12 + 12 12 + 12 + 12 + 9 + 9
24 + 24 18 + 18 + 18 18 + 18 + 12 + 12 18 + 12 + 12 + 9 + 9

24 + 9 + 9 24 + 12 + 12 + 9 12 + 12 + 12 + 12 + 9

24 + 12 + 9 24 + 12 + 12 + 12 18 + 12 + 12 + 12 + 9
24 + 12 + 12 24 + 18 + 12 + 9 12 + 12 + 12 + 12 + 12

24 + 18 + 9


24 + 18 + 12


24 + 18 + 18



24 + 24 + 9


24 + 24 + 12


9,000 BTU Compatible Units

12,000 BTU Compatible Units

  • Wall Mounted: WT012GLSI24HLG (36-1/4 x 7-5/8 x 12 inches WDH)
  • Ceiling Cassette: CT012GLSILCFHG (22-1/2 x 22-1/2 x 9-5/8 inches WDH)
  • Ductable Concealed: RT012GLSILCFHG (27-1/2 x 19-1/4 x 7-7/8 inches WDH)

18,000 BTU Compatible Units

  • Wall Mounted: WT018GLSI24HLG (43-1/8 x 8-3/4 x 13 inches WDH)
  • Ceiling Cassette: CT018GLSILCFHG (22-1/2 x 22-1/2 x 9-5/8 inches WDH)
  • Floor-Ceiling Flex Console: UT018GLSILCFHG (41-1/2 x 9-1/4 x 26-1/2 inches WDH)
  • Ductable Concealed: RT018GLSILCFHG (35-1/2 x 19-1/4 x 7-7/8 inches WDH)

    24,000 BTU Compatible Units

    • Wall Mounted: WT024GLSI24HLG (43-1/8 x 8-3/4 x 13 inches WDH)
    • Ceiling Cassette: CT024GLSILCFHG ( 33-1/8 x 33-3/4 x 10-3/4 inches WDH)
    • Floor-Ceiling Flex Console: UT024GLSILCFHG (41-1/2 x 9-1/4 x 26-1/2 inches WDH)
    • Ductable Concealed: RT024GLSILCFHG ( 43-1/4 x 17-3/4 x 7-7/8 inches WDH)

    Min. / Max. Loading

    18,000 / 63,000 BTU/h.

    Notes

    • Different models of all available matching indoor units can be combined in any order to create a multi zone split system, up to a quantity of the number of available circuits.
    • Not all available circuits need to be utilized with an attached indoor unit. 66% or higher of the total capacity utilization is recommended.
    • Every indoor unit attached to a multi zone system will operate at a random, self-regulated capacity, based on the actual demand it measures from the zone it is serving (Between 30% to 100% of its rated capacity) or turn OFF as needed.
    • Outdoor unit will also self-regulate its total output capacity, based on the total demand it reads from all the simultaneously running indoor units at any given moment, up to its maximum rating capacity.
    • With multi split systems, the total demand from the outdoor unit, will seldomly exceed 75% of the total available capacity of the combined indoor unit group due to load fluctuations of each indoor unit.
    • Therefore, total attached indoor unit capacity can be selected up to 133% of the supporting outdoor unit's rated capacity.
    • Although very seldom, if the total demand from the combined group of indoor units' exceeds the rated capacity of the outdoor unit, the capacity of the each indoor unit will be annotated accordingly.
    • For high demand applications, max loading limits may need to be reduced up to 20% to avoid underperformance risks during some extreme conditions.
    Pioneer® Product Series

    Multi-Zone Quantum Ultra™ Mini Split Outdoor Units

    Empower zone heating and cooling throughout your entire building with a multi-zone mini split condenser from Pioneer. Multi-zone systems can power multiple indoor mini split units from a single condenser. With a multi-zone outdoor unit, one exterior unit connects and simplifies your entire system. Multi-zone systems minimize the number of outdoor units necessary to bring premium temperature control to your home. A single multi-zone outdoor unit serves up to eight indoor units. Minimizing the number of units you need improves the look of your building’s exterior, which boosts curb appeal for your home or commercial building.

    IMPORTANT
    The outdoor unit is pre-charged with
    R454b Refrigerant, allowing refrigerant line lengths of up to 25 ft. per circuit.

    Notes

    • Different models of all available matching indoor units can be combined in any order to create a multi-zone split system, up to a quantity of the number of available circuits.
    • Not all available circuits need to be utilized with an attached indoor unit. 66% or higher of the total capacity utilization is recommended.
    • Every indoor unit attached to a multi-zone system will operate at a random, self-regulated capacity, based on the actual demand it measures from the zone it is serving (Between 30% to 100% of its rated capacity) or turn OFF as needed.
    • Outdoor unit will also self-regulate its total output capacity, based on the total demand it reads from all the simultaneously running indoor units at any given moment, up to its maximum rating capacity.
    • With multi-split systems, the total demand from the outdoor unit, will seldomly exceed 75% of the total available capacity of the combined indoor unit group due to load fluctuations of each indoor unit.
    • Therefore, total attached indoor unit capacity can be selected up to 133% of the supporting outdoor unit's rated capacity.
    • Although very seldom, if the total demand from the combined group of indoor units exceeds the rated capacity of the outdoor unit, the capacity of the each indoor unit will be annotated accordingly.
    • For high demand applications, max loading limits may need to be reduced up to 20% to avoid underperformance risks during some extreme conditions.

    What's Included in Your Purchase

    • Outdoor Unit
    • Installation Manual
    • User’s Manual

    Product Warranty

    Warranty Registration is required within 90 days of purchase. Please, check our Warranty Policy

    • Up to 5 years Warranty for Parts
    • Up to 5 years Warranty for Compressor

    Manuals & Documents

    Questions & Answers

    Have a Question?

    Be the first to ask a question about this.

    Ask a Question