Energy-Star
Pioneer® Hyperformance™ 12,000 BTU 23.5 SEER2 Ductless Mini Split Inverter++ Energy-Star Wi-Fi Air Conditioner Hyper Heat Pump Full Set 230V
Pioneer® Hyperformance™ 12,000 BTU 23.5 SEER2 Ductless Mini Split Inverter++ Energy-Star Wi-Fi Air Conditioner Hyper Heat Pump Full Set 230V
Out of stock
-
Estimated delivery if ordered today: Dec 11 - Dec 15
Couldn't load pickup availability
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Why buy from our store?
Overview
Summary
- Ultra Low Ambient Hyperformance™ Ductless Mini Split Hyper Heat Pump System
- Cooling capacity: 12,000 BTU/H (1 Ton) with 23.5 SEER2 / 12.7 EER2 efficiency
- Heating capacity: 12,000 BTU/H (1 Ton) with 9.5 HSPF2 / 3.74 COP efficiency
- Voltage: 208/230V, 60Hz, 1Ph
- High Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Hyper Heat Unit (Continues heating in -22°F weather)
- Wireless Internet Access Included (Via Free Smartphone App)
What's Included
- Indoor Unit
- Outdoor Unit
- Wireless Remote Control (with wall holder and batteries)
- Internet Control Module
- Copper Lines*
- Signal Cable Between Units*
- Drain for Indoor/Outdoor*
- Wall Passage Sleeve*
- Putty for Wall Hole*
- Leak Guard Sealer
- Wrapping Tape
- Installation Manual
- User’s Manual
*If ordered with an installation kit
Our Guarantee
- 5 years Warranty for Parts (Extendable to up to 7 years)
- 5 years for Compressor (Extendable to up to 10 years)
Features
[[FEATURES]]
Technical Information
Performance Data
- Power Supply: 208~230V, 60Hz, 1Ph
- Cooling Rated Capacity (BTU/hr): 12,000 (3,000 ~ 14,000)
- Rated Power Input (Cooling): 940W
- Rated Current (Cooling): 4.3A
- Cooling SEER2: 23.5 BTU/W.h
- Cooling EER2: 12.7 BTU/W.h
- Heating Rated Capacity (BTU/hr): 12,000 (3,000 ~ 16,000)
- Rated Power Input (Heating): 940W
- Rated Current (Heating): 4.3A
- Heating HSPF2 (Region IV/V): 11 / 9.5 BTU/W.h
- Heating C.O.P.2 (47°F/5°F): 3.74 / 1.98 W/W
-
Refrigerant Type/Weight: R410A/1.18kg
- Recommended Application Area: 200~550 Sq.Ft
Indoor Unit Data
- Part Number: WF012GHFI25HLH
- Air Flow (Hi/Med/Lo): 377 / 324 / 253 CFM
- Sound Level (Turbo/Hi/Med/Lo/Mute): 42/40/36/32/29 dB(A)
- Net Dimensions (WDH): 33-1/2 x 8-1/8 x 10-5/8 Inches
- Carton Dimensions (WDH): 35-1/2 x 10-1/4 x 13-1/8 Inches
- Net / Gross Weight: 18.7 / 23.1 Lbs
Outdoor Unit Data
- Part Number: YN012GHFI25RPH
-
Sound Level: 53 dB(A)
- Net Dimensions (WDH): 31-7/8 x 11 x 23 Inches
- Carton Dimensions (WDH): 37 x 15-1/8 x 25-1/4 Inches
- Net / Gross Weight: 72.6 / 79.2 lbs
- Electrical Circuit Size: 15A (double-pole)
Manuals & Documents
Energy-Star
Questions & Answers
Have a Question?
-
Is there a minimum line length from head to compressor for 12 k YH012GHF125rph
The minimum we recommend is 10 ft. That is the shortest that is supported by the precharged amount.The shortest possible is 5 ft but you'd need to remove an ounce of refrigerant to account for that. -
hyper heat manual says 12" from outside wall to unit. Just want to double check this is accurate. I have 2 other brands neither call for anything close to that much. You also sell the support brackets which hang on wall and I have never seen one which is capable of holding the back of the unit 12" off the wall.
This is accurate, the purpose is to prevent build-up of debris (such as leaves) between the unit and the wall, and provide optimal airflow. When mounted on the wall, the clearance drops to 4" since there is less risk of obstruction over time behind the unit, and a new dimension of airflow is opened by raising the system off the ground.

