Diamante Essenza™ High-Wall Series
Pioneer® Diamante Essenza™ 35,000 BTU 17 SEER2 230V High-Wall Ductless Mini-Split Air Conditioner Inverter Heat Pump with 16 Ft. Kit
Pioneer® Diamante Essenza™ 35,000 BTU 17 SEER2 230V High-Wall Ductless Mini-Split Air Conditioner Inverter Heat Pump with 16 Ft. Kit
Available in stock
-
Estimated delivery if ordered today: Apr 23 - Apr 27
Couldn't load pickup availability
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Why buy from our store?
Your Purchase Includes:
Outdoor Condenser
Pre-charged from the factory with enough R32 refrigerant to accomodate up to 25' lineset lengths, and equipped with intelligent self-defrost.
Indoor Air Handler
Whisper-silent and beautifully sleek, it mounts onto the wall and features a washable, re-usable dust filter and an easy-to-use self-clean mode for easy maintenance.
16' Installation Kit
Included with system purchase is the full installation kit which features a 16' insulated copper lineset, 16' signal cable between units, and a 10' drain hose.
Handheld Remote
Functional in form and easy-to-read, the remote offers all of the essential features like Cool, Heat, Dry and Fan modes, as well as I FEEL to detect nearby temperature.
Summary
- Standard Efficiency Diamante Essenza Ductless Mini Split Heat Pump System
- Cooling capacity: 35,000 BTU/H with 17.0 SEER2 / 9.5 EER2 efficiency
- Heating capacity: 35,400 BTU/H with 8.5 HSPF2 / 3.2 COP2 efficiency
- Voltage: 208/230V, 60Hz, 1Ph
- High Wall-Mounted Ductless Air Conditioning & Heating System
- Variable-Speed DC Inverter Driven Performance
- Factory-Precharged with Environmentally Friendly R-32 Refrigerant
- Standard Ambient Range Operation (As low as 5°F in Heating / As high as 122°F in Cooling)
Features
- Heat Pump with Cooling, Heating, Dry, and Ventilation Modes
- Dual-Drainage Ports
- Washable, Reusable Air Filters
- Dual-Axis Airflow (Motorized Up-Down and Left-Right Louvers)
- Functional Remote with:
- ECO and SLEEP Modes, for Energy-Conservation
- Timer On/Off Control
- TURBO, for Times of High-Demand
- Self-Clean Cycle
- MEMORY, to Recall Favorite Settings
- IFEEL, to Detect and Adjust to Local Temperature
Technical Information & Performance
-
System Kit
- Power Supply: 208~230V, 60Hz, 1Ph
- Cooling Rated Capacity: 35,000 BTU/h
- Cooling Capacity Range: 7,500~36,000 BTU/h
- Cooling SEER2: 17.0 BTU/W.h
- Cooling EER2: 9.5 BTU/W.h
- Heating Rated Capacity: 35,400 BTU/h
- Heating Capacity Range: 7,500~36,000 BTU/h
- Heating HSPF2 (Region IV/V): 8.5 / 7.5 BTU/W.h
- Heating C.O.P.2 (47°F/5°F): 3.2 / 1.8 W/W
- Refrigerant Type: R-32
- Recommended Room Size: 1,000~1,400 sq ft
- Minimum Room Size: 63 sq ft
- Piping Diameter: 5/8" (Gas) / 1/4" (Liquid)
- AHRI Reference: 217048738
-
Indoor Unit
- Part Number: WT036GLUI17HLD
- Air Flow (Turbo/Hi/Med/Lo/Mute): 882 / 741 / 564 / 458 / 411 CFM
- Sound Level (Turbo/Hi/Med/Lo/Mute): 55 / 52 / 46 / 41 / 39 dB(A)
- Product Dimensions (WDH): 46"-7/8 x 10"-1/4 x 14"-1/4 Inches
- Carton Dimensions (WDH): 49"-5/8 x 12"-7/8 x 16"-7/8 Inches
- Net / Gross Weight: 38.6 / 46.3 lbs
-
Outdoor Unit
- Part Number: YN036GLUI17RPD
- Breaker Needed: 35A (double-pole)
- Sound Level: 63 dB(A)
- Net Dimensions (WDH): 38"-1/2 x 16"-1/2 x 31"-5/8 Inches
- Carton Dimensions (WDH): 40"-1/4 x 18"-7/8 x 32"-7/8 Inches
- Net / Gross Weight: 105.8 / 120.2 lbs
Dimension Chart
Diamante Essenza™ High-Wall Series
Questions & Answers
Have a Question?
-
In a question someone asked about 10 -2 wire you answered 10-2 wire is correct and stated you need a 30 amp double pull breaker but the data sheet says you need a 35 amp double pull breaker which one is correct
In nearly all cases the 10 AWG wire does not need sizing up to the next thickness until 40A. Regardless, the 35A spec is the maximum allowable breaker size, any breaker size between 25 and 35A is perfectly suitable. 30A is the most commonly found size, so we recommend 30A.
-
Do I need a neutral wire or just #10 2 wire with a ground?
This would take a 30A double-pole breaker. The corresponding wire would be 10 AWG, with 2 hots and a ground, no neutral.
-
Is this considered a 3 ton?
A ton is equivalent to 12,000 BTUs. Therefore 36,000 BTUs would be the same as 3 tons.
-
Is this diy?
That is entirely dependent on your skillset and comfort level. Many customers hire a technician to perform the installation, and many others opt to self-install the system. It's up to your preference. They can be DIY installed with proper preparation. The outside unit is factory pre-charged and the line sets are pre-flared to make it simple. It would be a medium-advanced project. The only part needing any specific knowledge is vacuuming the lines using a pump and pressure gauge prior to releasing the refrigerant into the lines, a step which can be bypassed using our easy to use Kwik-E-Vac line set flushing tool which skips that process.
-
DOES THIS UNIT NEED GAS CONNECTION ?
No, this is an all-electric system.